Particle Size 5, 10 |
Recommended Use Separation of small organics (1 K - 15 K MW) |
Columns:
Phenogel 5 µm 500 Å x 2, 103 Å, 104 Å |
Dimension:
300 x 7.8 mm |
Part No.:
00H-0443-K0 (500 Å) 00H-0444-K0 (103 Å) 00H-0445-K0 (104 Å) |
Solvent:
THF |
Flow Rate:
1 mL/min |
Temperature:
25 °C
|
Detection:
Rl
|
Sample:
Phenolic Aldehyde Resin, MW 500 to 470 K
|
Columns:
Phenogel 5 μm 50 Å, 100 Å, 500 Å
|
|
Dimension:
300 x 7.8 mm
|
|
Part No.:
00H-0441-K0 (50 Å) 00H-0442-K0 (100 Å) 00H-0443-K0 (500 Å) |
|
Solvent:
THF |
|
Flow Rate:
1 mL/min |
|
Temperature:
25 °C |
|
Detection:
Differential Refractometer |
|
Sample:
1. dp7
2. dp6 3. dp5 4. dp4 5. dp3 6. dp2 7. dp1 |
1. dp7 546 MW
2. dp6 458 MW 3. dp5 370 MW 4. dp4 282 MW 5. dp3 194 MW 6. dp2 106 MW 7. dp1 62 MW |
Columns:
Phenogel 5 μm 50 Å, 100 Å, 500 Å
|
|
Dimension:
300 x 7.8 mm
|
|
Part No.:
00H-0441-K0 (50 Å) 00H-0442-K0 (100 Å) 00H-0443-K0 (500 Å) |
|
Solvent:
THF |
|
Flow Rate:
1 mL/min |
|
Temperature:
25 °C |
|
Detection:
Differential Refractometer |
|
Sample:
1. C40
2. C32 3. C24 4. C20 5. C16 6. C13 |
562 MW
450 MW 338 MW 282 MW 226 MW 184 MW |
Columns:
Phenogel 5 µm 105 Å, 104 Å, 103 Å, 500 Å |
Dimension:
300 x 7.8 mm |
Part No.:
00H-0446-K0 (105 Å) 00H-0445-K0 (104 Å) 00H-0444-K0 (103 Å) 00H-0443-K0 (500 Å) |
Solvent:
THF |
Flow Rate:
1 mL/min |
Detection:
Differential Refractometer
|
Injection Volume:
100 µL 0.25 % w/v
|
Sample:
1. 680,000 MW
2. 90,000 MW 3. 30,000 MW 4. 6,000 MW |
Columns:
Phenogel 5 µm 105 Å, 104 Å, 103 Å, 500 Å |
Dimension:
300 x 7.8 mm |
Part No.:
00H-0446-K0 (105 Å) 00H-0445-K0 (104 Å) 00H-0444-K0 (103 Å) 00H-0443-K0 (500 Å) |
Solvent:
THF |
Flow Rate:
1 mL/min |
Detection:
Differential Refractometer
|
Injection Volume:
100 µL 0.25 % w/v
|
Sample:
1. 700,000 MW
2. 107,000 MW 3. 27,000 MW |
Columns:
Phenogel 5 µm 105 Å, 104 Å, 103 Å, 500 Å |
Dimension:
300 x 7.8 mm |
Part No.:
00H-0446-K0 (105 Å) 00H-0445-K0 (104 Å) 00H-0444-K0 (103 Å) 00H-0443-K0 (500 Å) |
Solvent:
THF |
Flow Rate:
1 mL/min |
Detection:
Differential Refractometer
|
Injection Volume:
100 µL 0.25 % w/v
|
Sample:
1. 420,000 MW
2. 24,000 MW 3. 2,500 MW 4. 500 MW |
Columns:
Phenogel 5 μm 50 Å, 100 Å, 500 Å
|
|
Dimension:
300 x 7.8 mm
|
|
Part No.:
00H-0441-K0 (50 Å) 00H-0442-K0 (100 Å) 00H-0443-K0 (500 Å) |
|
Solvent:
THF |
|
Flow Rate:
1 mL/min |
|
Temperature:
Ambient |
|
Detection:
Differential Refractometer |
|
Injection Volume:
100 μL 0.25% w/v |
|
Sample:
1. dp7
2. dp6 3. dp5 4. dp4 5. dp3 6. dp2 7. dp1 | 546 MW
458 MW 370 MW 282 MW 194 MW 106 MW 62 MW |
Columns:
Phenogel 5 µm 50 Å, 100 Å, 500 Å |
Dimension:
300 x 7.8 mm |
Part No.:
00H-0441-K0 (50 Å)00H-0442-K0 (100 Å) 00H-0443-K0 (500 Å) |
Solvent:
THF |
Flow Rate:
0.8 mL/min |
Column Temp.
30° C
|
Detection:
RI (35° C)
|
Injection Volume:
40 µL
|